IDS2000 Multi-parameter Drilling Instrumentation System
Product Details:
| Place of Origin | Hubei, China |
|---|---|
| Brand Name | SY |
| Model Number | IDS2000 |
Detailed Product Description
IDS2000 Drilling Instrumentation System is developed and co-manufactured by American Petron Inc. and Hubei Jianghan Petroleum Instrument & Meter Co., Ltd.(JPIM) for various drilling rigs and workover rigs to test and display hook load, weight on bit, rotary torque, standpipe pressure, tong torque, Rotary RPM, SPM Pump #1,2 &3, accumulated SPM, inlet mud volume, total mud in, mud return flow, mud pit 1# ~ 6 # volume, total mud pit volume, content of total hydrocarbon, and H2S, position of traveling block, well depth and other parameters during drilling, and help the driller to judge the operating situation of drilling rigs.
All the parameters are acquired, calibrated, displayed and alarmed through IDS2000 System and then the data are transmitted to PNT software by remote communication for display, record, alarm and print. The key data acquisition control (as IDS2000 unit), display and relevant processing software of the system are from American Petron Inc. to ensure high technology and performance. Combined with tens of years experience of weight indicator system manufacture, JPIM can provide its customers complete service in all directions. Technical Specifications
1. Working temperature: -30~70
2. Relative humidity: 0~90%
3. Hook load and weight on bit
3.1) Range: 0~500×10 kN
2) Error: ≤±1.5%F·S
4. Rotary torque:
1) Range: 0~40kN·m (display method: 0~500grades)
2) Error: ≤±5%F·S
5. Tong torque:
1) Range: 0~100kN (tail line pull)
2) Error: ≤±2.5%F·S
6. Standpipe pressure:
1) Range: 0~40MPa
2) Error: ≤±1.5%F·S
7. RPM
Range: 0~300r/min
8. SPM
Range: 0~300s/min
9. Mud flow
1) Range: 0~100%
2) Error: ≤±2%F·S
10. Mud pit volume: 0~999.9m3
11. Well Depth:
1) Range: 0~9999.9m
2) Error: ≤±0.5%F·S
12. Total Hydrocarbon:
1) Range: 0~100%LEL (the lower concentration limit of explosive hydrocarbon gas)
2) Error: ≤±5%F·S
3) Response time: less than 15seconds (90% response)
4) Farthest installation position: 1000m
13. H2S:
1) Range: 0~100ppm
2) Error: ≤±5%F·S
3) Response: less than 60seconds
4) Farthest installation position: 1000m
14. Working voltage: 220VAC±10%, 47~63Hz
110VAC±10%, 47~63Hz
IDS2000 Multi-parameter Drilling Instrumentation System
Other Products from this Supplier
See more
Multi-parameter Drilling Instrumentation, H2S content, ton mile products from this supplier.
Product Showcase[30]
Company Info
Hubei Jianghan Petroleum Instrument & Meter Co., Ltd.
[China]
[Verified Member]
City: Wuhan
Province/State: Hubei
Country/Region : China
Business Type:Manufacturer
Online Postings: Products